JLG 1100SJP Operator Manual User Manual

Page 116

Advertising
background image

SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-16

– JLG Lift –

3121255

4.

Wheel Drive Hub

Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200

hours of operation

Comments - Place Fill port at 12 o’clock position and

Check port at 3 o’clock position. Pour lubricant into fill
port until it just starts to flow out of check port.

5. Hydraulic Return Filter

Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator

6. Hydraulic Charge Filter

Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.