Platform control indicator panel, Platform control indicator panel -17 – JLG 1100SJP Operator Manual User Manual

Page 49

Advertising
background image

SECTION 3 - MACHINE CONTROLS AND INDICATORS

3121255

– JLG Lift –

3-17

Platform Control Indicator Panel

(See Figure 3-7., Platform Control Indicator Panel - 1100S or
Figure 3-8., Platform Control Indicator Panel - 1100SJP)

1. Level System Fault Indicator

Indicates a fault in the electronic leveling system. The
fault indicator will flash and an alarm sound. All func-
tions will default to creep if the boom is extended past
transport mode (24 inches [61 cm]) or elevated more
than 15° above horizontal.

IF THE LEVEL SYSTEM FAULT INDICATOR IS ILLUMINATED, SHUT
DOWN THE MACHINE, RECYCLE THE EMERGENCY STOP, AND
RESTART THE MACHINE. IF THE FAULT PERSISTS, RETURN THE PLAT-
FORM TO THE STOWED POSITION, USING MANUAL LEVELING AS
REQUIRED, AND HAVE LEVELING SYSTEM REPAIRED.

2. AC Generator (If equipped)(1100SJP Only)

Indicates the generator is in operation.

3. Platform Capacity Indicator

Indicates the maximum platform capacity for the plat-
form.

On 1100SJP models, one of the capacity lights should
be on at all times. Both lights will flash and an alarm will
sound if the platform is out of the operating envelope for
the selected capacity.

4. Tilt Alarm Warning Light

Indicates that the chassis is on a slope (over 5 degrees).
If the boom is above transport position or telescope out
and the machine is on a 5 degree slope, an alarm will
sound and CREEP is automatically activated.

IF ILLUMINATED WHEN BOOM IS RAISED OR EXTENDED, RETRACT
AND LOWER TO BELOW HORIZONTAL THEN REPOSITION MACHINE SO
THAT IT IS LEVEL BEFORE EXTENDING BOOM OR RAISING BOOM
MORE THAN 15 DEGREES ABOVE HORIZONTAL.

Advertising
This manual is related to the following products: