JLG 3969electric Operator Manual User Manual

Page 10

Advertising
background image

SECTION 1 - SAFETY PRECAUTIONS

1-2

– JLG Sizzor –

3120880

1.3

ELECTROCUTION HAZARD

DO NOT MANEUVER MACHINE OR PERSONEL INSIDE PROHIB-
ITED ZONE. ASSUME ALL ELECTRICAL PARTS AND WIRING ARE
ENERGIZED UNLESS KNOWN OTHERWISE.

NOTE: MAINTAIN M.S.A.D. FROM ALL OTHER CHARGED

LINES AND PARTS AS WELL AS THOSE SHOWN.

• MAINTAIN SAFE CLEARANCE FROM ELECTRICAL

LINES AND APPARATUS. ALLOW FOR PLATFORM
SWAY, ROCK OR SAG AND ELECTRICAL LINE SWAY-
ING. THE MACHINE DOES NOT PROVIDE PROTEC-
TION FROM CONTACT WITH OR PROXIMITY TO AN
ELECTRICALLY CHARGED CONDUCTOR.

• MAINTAIN A CLEARANCE OF AT LEAST 3 METERS

(10 FEET) BETWEEN ANY PART OF THE MACHINE
OR ITS LOAD AND ANY ELECTRICAL LINE OR APPA-
RATUS CARRYING UP TO 50,000 VOLTS. 0.3 METER
(ONE FOOT) ADDITIONAL CLEARANCE IS REQUIRED
FOR EVERY ADDITIONAL 30,000 VOLTS OR LESS.

Table 1-1.

Minimum Safe Approach Distances (M.S.A.D.) to energized (exposed or insulated) power lines and parts

VOLTAGE RANGE

(Phase To Phase)

MINIMUM SAFE APPROACH DISTANCE

Meters (Feet)

0 to 300V

AVOID CONTACT

Over 300V to 50KV

3 (10)

Over 50KV to 200KV

5 (15)

Over 200KV to 350KV

6 (20)

Over 350KV to 500KV

8 (25)

Over 500KV to 750KV

11 (35)

Over 750KV to 1000KV

14 (45)