13 diagnostic trouble codes (dtc) on ground module, 1 gauge fault code display, 2 fault codes – JLG G5-18A Service Manual User Manual

Page 154: Diagnostic trouble codes (dtc) on ground module, Gauge fault code display, Fault codes

Advertising
background image

Electrical System

9-34

G5-18A, 2505H, 25.5

9.13

DIAGNOSTIC TROUBLE CODES
(DTC) ON GROUND MODULE

9.13.1

Gauge Fault Code Display

Fault codes will appear in the display area (7) of the gauge (8).

9.13.2

Fault Codes

M 9030

Y

7

8

Help Message

DTC

Trigger / Possible

Symptom

Actions

Latch / Reset

Condition

System OK

1

The Ground Module detects
no problems exist

-

-

Power Cycle

211

Power was cycled on

-

-

Load Moment
Shutoff Input -
Invalid Signal

2336

LSI Cancel Switch
depressed at Startup or for
longer than 40seconds

Default machine to LSI
Cutout (if not in passive
mode and not in LSI
calibration mode) and
disregard LSI Cancel
Switch Input override

Latched. Check wiring to
Pin J1-3 on the Ground
Module and integrity of
mechanical switch

Lift Down Valve -
Short to Battery

335

The module is detecting
short to B+

Deactivate Lift Down Valve
Output. Also deactivate Lift
Enable if machine is in
LSI Cutout

Latched. Check wiring to
Pin J1-8 on the Ground
Module

Lift Down Valve -
Open Circuit

336

The module is detecting an
open circuit

Deactivate Lift Down
Output

Latched. Check wiring to
Pin J1-8 on the Ground
Module

Telescope Out
Valve - Short to
Battery

33123

The desired current is 0mA
and the digital output driver’s
diagnostic feedback is low
for a period of 250ms

Deactivate Telescope Out
Output. Also deactivate
Telescope Enable if
machine is in LSI Cutout

Latched. Check wiring to
Pin J1-9 on the Ground
Module

Lift Enable Valve –
Short to Ground

33159

The module is detecting a
short to ground

Deactivate Lift Enable
Output

Latched. Check wiring to
Pin J1-7 on the Ground
Module

Lift Enable Valve –
Open Circuit

33160

The module is detecting an
open circuit

Deactivate Lift Enable
Output

Latched. Check wiring to
Pin J1-7 on the Ground
Module

Advertising