JLG G5-18A Service Manual User Manual

Page 156

Advertising
background image

Electrical System

9-36

G5-18A, 2505H, 25.5

Conflicting Drive
Direction Signals

462

This fault can only be
present if the machine is
configured for the CE
market. Both passive mode
inputs (fwd/park brake off
AND rev/park brake off) are
present concurrently

Default machine to
Active Mode

Latched. Check wiring to
Pins J1-5 on Ground
Module and Pin J1-4 on
Remote IO Module

CAN Bus Failure –
LSI

6638

Ground Module lost CAN
bus communication with LSI
module and no messages
have been received for a
period of
1 second

Default machine to LSI
Cutout if not in passive
mode with operation only
available via LSI Cancel
switch (Creep Mode
operation)

Not Latched
Revert to normal
operation when CAN
bus communication is
re-established

CAN Bus Failure -
Remote Input
Module

6642

Ground Module lost CAN
bus communication with
Remote Input Module and
no messages have been
received for a period of 250
ms

This fault can only occur if
the machine detects itself
to be a Tier 3 configuration:
Default machine to LSI
Cutout (if not in passive
mode or not in LSI
calibration mode) with
operation only available via
LSI Cancel switch (Creep
Mode operation)
This fault can only occur if
the machine detects itself
to be a Tier 4 configuration:
Deactivate all
Module Outputs

Not Latched
Revert to normal
operation when CAN
bus communication is
re-established

LSI Not Calibrated

8514

LSI CAN display indicates
calibration is required

Permit LSI-CAN display to
control its internal alarm

Not Latched. Once
calibrated sequence
performed, LSI display
indicates completion

LSI Load Cell A -
Out of Range

8516

LSI module detects condition
and OMD reading is 100%

Machine automatically in
LSI Cutout with operation
only available via LSI
Cancel Switch (Creep
Mode operation)
Permit LSI-CAN display to
control its internal alarm

Latched. Check LSI
gauge and sensor wiring

LSI Load Cell B -
Out of Range

8517

LSI module detects condition
and OMD reading is 100%

Machine automatically in
LSI Cutout with operation
only available via LSI
Cancel Switch (Creep
Mode operation)
Permit LSI-CAN display to
control its internal alarm

Latched. Check LSI
gauge and sensor wiring

Help Message

DTC

Trigger / Possible

Symptom

Actions

Latch / Reset

Condition

Advertising