JLG G5-18A Service Manual User Manual

Page 168

Advertising
background image

Electrical System

9-48

G5-18A, 2505H, 25.5

926

523720

8

Urea supply module heater temperature; duty cycle in invalid range

927

523721

11

Urea supply module temperature measurement not available

928

523722

8

Urea supply module PWM signal; period outside valid range

929

523722

8

Detect faulty PWM signal from Supply Module

930

523721

8

Urea supply module temperature; duty cycle in failure range

931

523721

8

Urea supply module temperature; duty cycle in invalid range

932

29

3

Hand throttle idle validation switch; short circuit to battery

935

91

3

Sensor error accelerator pedal; signal range check high

936

29

3

Sensor error hand throttle; signal range check high

937

29

4

Hand throttle idle validation switch; short circuit to ground

940

91

4

Sensor error accelerator pedal; signal range check low

941

29

4

Sensor error hand throttle sensor; signal range check low

942

523921

3

Sensor error burner temperature; signal range check high

943

3532

3

Sensor error urea tank level; signal range check high

944

523921

4

Sensor error burner temperature; signal range check low

945

3532

4

Sensor error urea tank level; signal range check low

946

1079

13

Sensor supply voltage monitor 1 error (ECU)

947

1080

13

Sensor supply voltage monitor 2 error (ECU)

948

523601

13

Sensor supply voltage monitor 3 error (ECU)

956

677

3

Starter relay high side; short circuit to battery

957

677

4

Starter relay high side; short circuit to ground

958

677

5

Starter relay; no load error

959

677

12

Starter relay; power stage over temperature

960

677

3

Starter relay low side; short circuit to battery

961

677

4

Starter relay low side; short circuit to ground

963

523922

5

Burner shut off valve; open load

965

523922

3

Burner shut of valve; short circuit to battery

967

523922

4

Burner shut of valve; short circuit to ground

969

624

5

SVS lamp; open load

970

624

12

SVS lamp; power stage over temperature

971

624

3

SVS lamp; short circuit to battery

972

624

4

SVS lamp; short circuit to ground

973

523612

14

Software reset CPU SWReset 0

974

523612

14

Software reset CPU SWReset 1

975

523612

14

Software reset CPU SWReset 2

976

91

11

Plausibility error between APPl and APP2 or APPl and idle switch

980

523550

12

T50 start switch active for too long

981

172

3

Sensor error intake air; signal range check high

982

172

4

Sensor error intake air sensor; signal range check low

983

172

2

Intake air sensor; plausibility error

984

523921

11

Sensor burner temperature; plausibility error

986

523921

0

Physical range check high for burner temperature

989

523921

1

Physical range check low for burner temperature

994

105

3

Sensor error charged air temperature; signal range check high

Fault

Codes

SPN

Codes

FMI

Codes

Deutz Description

Advertising