Electrical System

Note: If the test weight is not known, follow steps 1 & 2.

1. With the estimated test weight on the forks, start the

machine and extend the boom horizontally until the
machine starts to tip. This point should be at an
extension of Xtip (1) of the second boom section. If
the machine is not tipping at this extension, weight
needs to be added or removed from the forks.

2. By confirming that the machine tips at this point, the

correct amount of weight is now on the forks.

3. The machine control system must be powered on for

at least 10 minutes before calibration.

4. The machine must be on a level surface with the

wheels steered straight and park brake OFF. Drive
the machine forward over a distance of at least 2 m
(6.5 ft) before entering a calibration point.

5. Place test weight on ground, apply park brake and

shut engine OFF. Do Not move machine.

Field Calibration Procedure:

Note: The following procedure must be completed
within 30 minutes of starting the procedure.

1. With ignition key in OFF position, press and hold

SYSTEM CHECK button on LSI display and turn
ignition key to engine START position. Release the
ignition key when engine start is achieved, but
continue to hold SYSTEM CHECK button on LSI
display until the orange LED on LSI display goes out
and buzzer sounds (approximately 3 seconds).
Release SYSTEM CHECK button.

2. The LEDs will perform a sequence. When only the

third green LED illuminates, press the SYSTEM
CHECK button.

3. The first green LED then illuminates. With no

attachment and boom retracted, lift boom fully.

4. Press the SYSTEM CHECK button on the LSI

display and release. The first 3 green LEDs will
illuminate. The third then second green LEDs will go
out as the calibration point is recorded.

5. The first green LED goes out and buzzer sounds

then the red LED illuminates.

6. Lower boom and without moving the machine, pick

up the proper test weight (W) listed in the table.

7. With the boom horizontal, slowly extend the boom to

the distance of Xcal (2). The proper calibration
weight is now on the rear axle and the LSI can now
be calibrated.

8. Press the SYSTEM CHECK button on the LSI

display and release. As the calibration point is
recorded, buzzer sounds and the LEDs will flash and
perform a sequence until all are flashing.

9. Turn the ignition key to OFF. LSI is now calibrated.

Model

Test Weight (W)

Xtip (1)

Xcal (2)

L2906H,

29.6LP

2100 kg

(4630 lb)

1256 mm

(49 in)

698 mm

(27 in)

2906H,

29.6

2100 kg

(4630 lb)

1256 mm

(49 in)

698 mm

(27 in)

3507H,

35.7

2100 kg

(4630 lb)

1758 mm

(69 in)

1043 mm

(41 in)

MZ5990

1

L2906H, 2906H, 3507H, 29.6LP, 29.6 & 35.7

MZ5990

2

L2906H, 2906H, 3507H, 29.6LP, 29.6 & 35.7