Electrical system – JLG 723A Service Manual User Manual

Page 178

Advertising
background image

Electrical System

9.70

L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7

FORK TILT VALVES
– SHORT TO
BATTERY

33192

1

Deactivate output J2-8 Fork Tilt Up

Valve.

Deactivate output J2-19 Fork Tilt

Down Valve.

Decouple/disable current feedback

input J3-6 Tilt Return (Disables

Fork Tilt Up and Down).

The UGM detects a short to battery

at this output.

Power cycled.

FORK TILT UP
VALVE – SHORT TO
GROUND

33193

1

Deactivate output J2-8 Fork Tilt Up

Valve.

Decouple/disable current feedback

input J3-6 Tilt Return (Disables

Fork Tilt Up and Down).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

FORK TILT DOWN
VALVE –
OPEN CIRCUIT

33194

1

Deactivate output J2-19 Fork Tilt

Down Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

FORK TILT DOWN
VALVE – SHORT TO
GROUND

33195

1

Deactivate output J2-19 Fork Tilt

Down Valve.

Decouple/disable current feedback

input J3-6 Tilt Return (Disables

Fork Tilt Up and Down).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

AUXILIARY FUNC-
TION-A VALVE –
OPEN CIRCUIT

33196

1

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate and inhibit the

Continuous Auxiliary Hydraulics

feature.

Turn OFF the Continuous Auxiliary

Hydraulics indicator.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

AUXILIARY
FUNCTIO-A/B
VALVES – SHORT
TO BATTERY

33197

1

Deactivate output J2-9 Auxiliary

Function-A Valve.

Decouple/disable current feedback

input J3-14 Aux Return (Disables

Auxiliary Function-A and

Function-B).

Deactivate and inhibit the

Continuous Auxiliary Hydraulics

feature.

Turn OFF the Continuous Auxiliary

Hydraulics indicator.

The UGM detects a short to battery

at this output.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until