Electrical system – JLG 723A Service Manual User Manual

Page 163

Advertising
background image

9.55

L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7

Electrical System

CONTINUOUS
AUXILIARY
HYDRAULICS
SWITCH HIGH AT
POWER UP

2122

1

Inhibit operation of the Continuous

Auxiliary Hydraulics feature/logic.

The UGM has detected the

Continuous Auxiliary Hydraulics

switch is HIGH at system power up.

The input

goes LOW for

a period of at

least 1

second.

JOYSTICK
TRIGGER SWITCH
ACTIVE AT POWER
UP

2123

1

Ignore command signals from the

joystick trigger switch that was

active during the power-up.

At system power-up, if the joystick

trigger switch is activated on CAT

models only.

A CAN

message is

received

indicating the

joystick

trigger switch

is not

activated.

JOYSTICK LEFT
ROLLER NOT IN
THE NEUTRAL
POSITION AT
POWER UP

2124

1

Ignore command signals from the

joystick regarding the left roller.

At system power-up, if the left roller

of the joystick is not in the neutral

position on CAT models only.

Latch fault

until a joystick

CAN message

is received

indicating the
roller is in the

neutral

position.

JOYSTICK RIGHT
ROLLER NOT IN
THE NEUTRAL
POSITION AT
POWER UP

2125

1

Ignore command signals from the

joystick regarding the right roller.

At system power-up, if the right

roller of the joystick is not in the

neutral position on CAT models

only.

Latch fault

until a joystick

CAN message

is received

indicating the
roller is in the

neutral

position.

BOOM RIDE
ENABLE SWITCH
NOT IN THE OFF
POSITION AT
POWER UP

2130

1

Ignore signal from the Boom Ride

Enable Switch.

At system power-up, the Boom

Ride/Boom Float module has

detected the Boom Ride Enable

Switch is engaged.

Boom Ride

Enable Switch

is detected in

its OFF

position.

PLATFORM
CONTROLS

22XXX

PLATFORM LEVEL –
CONFLICTING
INPUT SIGNALS

2225

1

Not acknowledge either platform

level function request messages.

If the UGM receives CAN2

messages that indicate both J1-9

and J1-10 inputs to the platform

controller are HIGH together.

Power cycled.

PLATFORM ROTATE
– CONFLICTING
INPUT SIGNALS

2226

1

Not acknowledge either platform

rotate function request messages.

If the UGM receives CAN2

messages that indicate both J1-7

and J1-8 inputs to the platform

controller are HIGH together.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until