9.5

L2906H, 2906H, 3507H, 619A, 723A, 29.6LP, 29.6, 35.7

Electrical System

9.5

SOFTWARE LEVEL 2 ACCESSIBILITY

The following parameters can be altered in the 2nd level of access to the machine’s software.

Refer to Section 9.17.2, “Analyzer Software - Version 3.5,”for detailed software information.

9.5.1

Operator Tools

9.5.2

Personalities

9.5.3

Calibrations

Function

Description

Change Anti Theft
Code

Allows the owner to change the Anti Theft Code

Perform Hardware
Exchange

Allows the owner to restore machine data (anti theft code, engine hours, machine
personalities, etc.) in the event that the machine controller or display/cluster gauge has
been replaced

Confirm Machine
Service

Allows the owner to turn off the Service Required Warning lamp when service is
performed

Review Service History

Allows the owner to see the last 15 times the Service Required Warning lamp was reset

Set Service Interval

Allows the owner to modify the default service interval of 100 hours

Cabin Joystick
Telescope: X-Axis/
Roller

Allows the owner to change/swap operation of the joystick Telescope and Fork Tilt
functions.

Function

Description

Default Value

Main Lift

Allows the owner to adjust the Max Lift Up & Max Lift Down function speeds

1400 mA

Soft Lift

Allows the owner to adjust the derate value when the boom enters the soft lift
zone

40%

Telescope

Allows the owner to adjust the Max Tele In & Max Tele Out function speeds

1450 mA (out)

1350 mA (in)

Fork Tilt

Allows the owner to adjust the Max Fork Tilt Up & Max Fork Tilt Down function
speeds

1350 mA (up)

1450 mA (down)

Aux.
Function

Allows the owner to adjust the Accel, Decel, and Max Function A & Max
Function B function speeds

1550 mA

Aux.
Momentary

Allows the owner to adjust the Max Momentary Aux A & Max Momentary Aux B
function speeds

1100 mA

Bucket
Mode

Allows the owner to adjust the Max Bucket Up & Max Bucket Down function
speeds

65 mA

Function

Description

Boom Angle

Allows the owner to calibrate the boom angle sensor if it is replaced. Refer to Section 9.14.10,
“Boom Angle Sensor.”