SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL

3120890

– JLG Lift –

3-5

3.4

CONTROLS AND INDICATORS

Ground Controls

PERFORM PRE-OPERATIONAL CHECKS AND INSPECTIONS
FROM THE GROUND CONTROL STATION. WHEN PERSONNEL
ARE IN THE PLATFORM, OPERATION OF THE BOOM WILL ONLY
BE PERFORMED WITH THE PERMISSION OF THE PLATFORM
OCCUPANT(S).

WHEN THE MACHINE IS SHUT DOWN THE MASTER/EMERGENCY
STOP SWITCH MUST BE POSITIONED TO THE “OFF” POSITION
TO PREVENT DRAINING THE BATTERY.

1.

Master Switch.

A two-position key operated switch furnishes bat-
tery power to the platform to the platform or ground
control switches when station power is selected
from the ground control panel and the master
switch is turned “ON”.

2.

Control Station Selector.

A three position, center off, key activated PLAT-
FORM/GROUND SELECT switch supplies power to
the platform control console when positioned to
PLATFORM. With the switch in the GROUND posi-
tion, power is shut off to the platform station, and
only the controls on the ground control panel are
operable.

NOTE: With the Platform/Ground Select Switch in the center

position, power is shut off to controls at both operat-
ing stations.

TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY
CONTROL LEVERS OR TOGGLE SWITCHES CONTROLLING
PLATFORM MOVEMENT DO NOT RETURN TO THE OFF POSITION
WHEN RELEASED.

3.

Ignition.

The machine is equipped with an on-off ignition
switch and a separate start push button switch on
the ground control panel which supplies electrical
power to the start solenoid when the ignition switch
is placed in the ON position and the START button
is depressed.

NOTE: Lift, Swing, and Telescope control switches are

spring-loaded and will automatically return to neutral
(off) when released.

WHEN OPERATING THE BOOM ENSURE THERE ARE NO PER-
SONNEL AROUND OR UNDER PLATFORM.

4.

Lift Control.

The three-position LIFT control switch provides rais-
ing and lowering of the main boom when positioned
to UP or DOWN.

5.

Telescope Control.

The three-position TELESCOPE control switch pro-
vides extension and retraction of the boom, when
positioned to IN or OUT.

6.

Swing Control.

The three-position SWING control switch provides
360 degrees continuous turntable rotation when
positioned to RIGHT or LEFT.

WHEN OPERATING ON AUXILIARY POWER, DO NOT OPERATE
MORE THEN ONE FUNCTION AT THE SAME TIME. SIMULTA-
NEOUS OPERATION CAN OVERLOAD THE AUXILIARY PUMP
MOTOR.

7.

Auxiliary Power Control.

A toggle type AUXILIARY POWER control switch
energizes the electrically operated auxiliary hydrau-
lic pump, when actuated. The switch must be held
in the ON position for the duration of auxiliary pump
use.

8.

Glow Plug Switch (Deutz Diesel Engine Only).

The push-button switch relays power to the glow
plugs used to warm the air intake on cold start oper-
ations.

Advertising