HYDRAULIC PRESSURE DIAGNOSIS

JLG Parts Department has a kit available to use for
hydraulic system maintenance and troubleshooting: the
JLG Pressure Test Kit. The kit is contained in a durable
polyethylene carrying case for demanding field service
conditions.

Pressure Test Kit

The hydraulic pressure test kit is used to pressure test the
various hydraulic components in the hydraulic system.
The kit includes:

• Gauges for testing high and low pressure circuits

• Fittings, couplers and hoses

• Durable carrying case

Contact your local authorized distributor for ordering
information.

8.3.1

Pressure Checks and Adjustments

When diagnosing trouble in the hydraulic system, use the
hydraulic testing information in Section 8.4.1, “Hydraulic
Pressures.”

In general, follow the steps below whenever conducting
pressure checks and performing adjustments:

1. Park the machine on a firm, level surface. Engage

the park brake, place the travel select lever in (N)
NEUTRAL, level the boom and turn the engine OFF.

2. The test port is located at the top right corner of the

main control valve. Install a pressure gauge capable
of measuring at least 10% more pressure than that
which the circuit being checked operates under.

3. Start the engine. Operate machine functions several

times to allow hydraulic oil to reach operating
temperature. The hydraulic oil temperature should
be between 100-120°F (38-49° C). If a temperature
gauge or thermometer is unavailable, the hydraulic
oil reservoir should be warm to the touch.

4. Refer to Section 8.4.1, “Hydraulic Pressures,” for

testing procedures.

5. Fully depress the accelerator pedal if required. Place

and hold the joystick in the position needed to
operate the particular machine function being
checked. Continue holding the joystick in position
until pressure readings are taken.

6. Check the pressure gauge reading. It should read as

specified in the Pressure Readings column of the
charts found in Section 8.4.1, “Hydraulic Pressures.”
If the reading is not as specified, turn the engine
OFF and check other components in the system.
Verify that all related hydraulic components and
electrical switches, sensors, solenoids, etc. are
operating correctly.

7. Adjust the relief valve by turning the adjustment

screw clockwise will increase the pressure; turning
the screw counterclockwise will decrease the
pressure.

8. Start the engine and check the pressure again. Turn

the engine OFF. If there is pressure reading in the
gauge, bleed it off then disconnect or remove the
pressure gauge from the machine.

Part

Number

Description

Approximate

Weight

Price and

Availability

70000652

Hydraulic Pressure Test

Kit

10 lbs.

Consult Factory

70000101

Digital Hydraulic

Pressure Test Kit

7 lbs.

Consult Factory

MZ1460

Advertising
This manual is related to the following products: