9-65

G6-42A, G9-43A, G10-43A

Electrical System

33200

Auxiliary Function -

B Valve - Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The auxiliary hydraulic “B” digital output was

shorted to ground. This fault may be caused by
improper wiring or a control module issue.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

441

Battery Voltage Too Low -

System Shutdown

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

Battery voltage is less than 8.0V so the control

module has prevented associated functionality.

No

442

Battery Voltage Too High -

System Shutdown

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

Battery voltage is greater than 8.0V so the control

module has prevented associated functionality.

Low-Side Fault Relay de-energized

Yes

447

Reference Voltage Out Of

Range

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

The control module’s +5V reference was

measured greater than 5.4V or less than 4.6V for
1000mS. Since this reference voltage supplies the
joystick(s), fork tilt and auxiliary hydraulic functions
must be prevented.

Low-Side Fault Relay de-energized

Yes

998

Eeprom Failure -

Check All Settings

Fork Tilt Up & Down, Auxiliary Hydraulics & De-

Clutch functionality prevented

The control module detected an issue with the

non-volatile memory used to retain Personalities
and Calibrations. Verify all settings using the JLG
Analyzer.

Low-Side Fault Relay de-energized

Yes

2239

Function Problem -

Joystick Calibration Faulty

Fork Tilt Up & Down, prevented

The joystick calibration has never been performed,

is improper or calibration attempt has failed. Re-
calibrate the Fork Tilt and Auxiliary Hydraulic
(optional) joysticks to clear this fault.

Auxiliary Hydraulics prevented if Machine Setup’s

AUX HYDRAULIC is ENABLED

No

DTC

Event

Comment

Latched