9-63

G6-42A, G9-43A, G10-43A

Electrical System

2358

Auxiliary Hydraulic Joystick -

Out Of Range Low

Auxiliary Hydraulic A & B prevented

The auxiliary joystick’s analog voltage was

measured to be less than 0.15V. Auxiliary
hydraulics will be prevented until the next power
cycle.

Active when Machine Setup’s AUX HYDRAULIC is

set to ENABLED

Yes

2397

Fork Tilt Joystick -

Voltage Disagreement

Fork Tilt Up & Down prevented

Analog feedback from the joystick’s tilt roller did

not agree within ±25% for 1000mS. Fork tilt up and
down will be prevented until the next power cycle.
This fault may be caused by improper wiring, a
joystick issue or a control module issue.

Yes

2398

Fork Tilt Joystick -

Out Of Range High

Fork Tilt Up & Down prevented

Analog feedback from the joystick’s tilt roller was

measured to be greater than 4.85V. Fork tilt up and
down will be prevented until the next power cycle.
This fault may be caused by improper wiring, a
joystick issue or a control module issue.

Yes

2399

Fork Tilt Joystick -

Out Of Range Low

Fork Tilt Up & Down prevented

Analog feedback from the joystick’s tilt roller was

measured to be less than 0.15V. Fork tilt up and
down will be prevented until the next power cycle.
This fault may be caused by improper wiring, a
joystick issue or a control module issue.

Yes

33191

Fork Tilt Valve -

Open Circuit

The desired current is greater than 250mA, but the

actual current is less then 75mA

The fork tilt up digital output was open-circuit. This

fault may be caused by improper wiring or a
control module issue.

Yes

33192

Fork Tilt Valve -

Short To Battery

Fork Tilt Up & Down, Auxiliary Hydraulics

functionality prevented

The fork tilt up or down digital output was shorted

to battery. Fork tilt up or down will be prevented
until the next powercycle. This fault may be caused
by improper wiring or a control module issue.

The desired current is greater than 250mA, but the

actual current is less than 75mA.

Yes

33193

Fork Tilt Up Valve -

Short To Ground

The actual current is greater than 200mA, PWM is

95%, and the digital output driver’s diagnostic
feedback is low

The fork tilt up digital output was shorted to

ground. This fault may be caused by improper
wiring or a control module issue.

Yes

DTC

Event

Comment

Latched