2 pressure specifications - g6-42a, Pressure specifications - g6-42a – JLG G6-42A Service Manual User Manual

Page 140

Advertising
background image

Hydraulic System

8-6

G6-42A, G9-43A, G10-43A

8.4.2

Pressure Specifications - G6-42A

Hydraulic

Circuit

Test Port

Procedure

Adjustment

Location

Pressure Range

Service/Park

Brake

TP (A)

Connect gauge to TP port, run engine at

low idle.

1

450 - 550 psi

(31,0 - 37,9 Bar)

Stand By

P1 (B)

Connect gauge to P1 port, run engine at

low idle.

2

550 - 650 psi

(37,9 - 44,8 Bar)

Steering

CF1 (C)

Connect gauge to CF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

Consult

Factory

2500 - 2700 psi

(172,3 - 186,1 Bar)

Boom Lift

EF1 (D)

Connect gauge to EF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

3

3800 - 4200 psi

(262,0 - 289,5 Bar)

Boom Retract

EF1 (D)

Connect gauge to EF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

3

3800 - 4200 psi

(262,0 - 289,5 Bar)

Boom Extend

EF1 (D)

Connect gauge to EF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

4

3800 ± 50 psi

(262,0 ± 3,4 Bar)

Fork Tilt

EF1 (D)

Connect gauge to EF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

5

4100 - 4500 psi

(282,6 - 310,2 Bar)

Frame Level

EF1 (D)

Connect gauge to EF1 port, run engine at

high idle, bottom out function. Hold over

relief and check pressure.

3

3800 - 4200 psi

(262,0 - 289,5 Bar)

MY0320

3

4

5

MY6010

1

2

A

B

C

D

Advertising