4 torque requirements, 5 lubrication, Torque requirements -3 – JLG 110HX ANSI Service Manual User Manual

Page 15: Lubrication -3

Advertising
background image

SECTION 1 - SPECIFICATIONS

3120636

– JLG Lift –

1-3

Machine Weight

100HX - 36,400 lbs. (16,511 kg)

110HX - 40,410 lbs. (18,330 kg)

100HX+10 - 39,685 lbs. (18,001 kg)

Machine Stowed Height

9 ft. 10 in. (3.0 m)

Machine Stowed Length

100HX - 36 ft. in. (11.0 m)

110HX - 38 ft. 7 in. (11.8 m)

100HX+10 - 44 ft. 2 in. (13.5 m)

Machine Width

With axles retracted - 8 ft. 6 in. (2.6 m)

With axles extended - 10 ft. 10 in. (3.3 m)

Wheelbase

11 ft. (3.4 m)

Maximum Tire Loads


1.4

TORQUE REQUIREMENTS

NOTE: See Procedure Section for tightening sequence of

turntable bearing bolts.

NOTE: When maintenance becomes necessary or a fas-

tener has loosened, refer to the Torque Chart to
determine proper torque value.

1.5

LUBRICATION

Ford LSG423 & LRG423 & LRG425 Engines

Single Viscosity Oils (SF, SF-SE, SF-CC, SF-CD)

Multi-Viscosity Oils (CD-SE, CD-SF)

* This viscosity can be used at colder temperatures only
with engine oil preheating.

Table 1-1.Maximum Tire Loads

Max. Load

Max Bearing Pressure

Description

Lbs.

Kg

PSI

kg/cm

2

100HX

19900

9027

145

10

100HX+10

23740

10769

172

11.8

110HX

21540

9771

156

10.7

When Outside Temp is Consistently

Use SAE Viscosity

Number

-10° to +60° F (-24° to +16° C)

*10W

+10° to +90° F (-12° C to +32° C)

20W-20

Above +32° F (0° C)

30

Above +50° F (+10° C)

40

When Outside Temp is Consistently

Use SAE Viscosity

Number

Below +10° F(-12° C)

*5W-20

(Synthetic)

Below +60° F(+16° C)

5W-30

-10° to +90° F(-24° to +32° C)

10W-30

Above -10° F(-24° C)

10W-40 or 10W-50

Above +20° F( -7° C)

20W-40 or 20W-50

Table 1-2.Torque Requirements

Description

Torque Value

Interval

Hours

Ft. Lbs.

Nm

Bearing to Chassis

220

298

50/600*

Bearing to Turntable

220

298

50/600*

Wheel Lugs

300

407

100

Turntable Springs

75

102

200

Boom Chains

59

80

500

Platform Rotator Bolt

140

190

500

* Check swing bearing bolts for security after first 50 hours of
operation and every 600 hours thereafter.

Advertising