SECTION 2 - PROCEDURES

3120636

– JLG Lift –

2-43

MEASURING POINT

MEASURING POINT

FORWARD

a. BOOM FULLY ELEVATED

AND FULLY RETRACTED

b. BOOM AT HORIZONTAL

AND FULLY EXTENDED

Figure 2-18. Swing Bearing Tolerance Boom Placement

MEASURING POINT

TURNTABLE REF.

FRAME REF.

SWING BEARING

Figure 2-19. Swing Bearing Tolerance Measuring Point