EASI-CLADDER™ PLUS

14

– JLG Accessory Manual –

3128112

DESCRIPTION

The cladding accessory when mounted to a scissor lift, is designed to lift
and position insulated wall panels for attachment to a structure on the con-
struction site. The main components are two panel loading frames with tele-
scoping/lifting panel handling arms installed on the scissor deck. The
frames are bolted to the scissor lift deck and are stabilized by C-shaped
brackets attaching them to the vertical posts of the scissor lift platforms’
handrail system.

The cladding accessory can be removed from the scissor lift deck when not
required on the job site. All electrical, hydraulic, and vacuum lines to the
cladding accessory are attached under the scissor deck using quick cou-
plers for easy disconnect.

SPECIFICATION

Table 3. - Platform: Ratings

3394RT

(7.25m - Dual Extension Decks Only)

500RTS

(with MegaDeck Only)

500RTS

(with Dual Extension Decks Only)

Max. Capacity

Persons

2

2

2

Wind

12.5 m/s

12.5 m/s

12.5 m/s

Outriggers

Required

Required

Required

Max. Platform
Capacity *

905kg - 385kg = 520kg

680kg - 385kg = 295kg

900kg - 385kg = 515kg

* Derated 385kg (850lb.) due to weight of cladding accessory mounted on platform deck.

Table 4. - Cladding Accessory Specifications

Requirement/Function

3394RT

(7.25m - Dual Extension Decks)

500RTS

(with MegaDeck)

500RTS

(with Dual Extension Decks)

Cladding Panel

Max. Panel Length

8m

8m

8m

Max. Panel Width

1.30m

1.30m

1.30m

Maximum Panel Weight

250kg

125kg

250kg

Max. Surface Irregularity
(for vacuum to hold)

Panel must be smooth and free of high ridges in the area where the vacuum cups attach to
the panel surface. The GREEN vacuum indicator light on the control box must be lit before

panel can be lifted upright 90° for installation.

Hydraulic Power Requirements

Pressure

3000psi

3000psi

3000psi

Flow

2gpm

2gpm

2gpm

Control Functions

Tether Control Box

Tether Control Box

Tether Control Box

Deck Extension

Dual, Powered

Dual, Powered

Dual, Powered

Electric Power Requirements for Vacuum Pump

Vacuum Pump

110 volt - 50Hz - 1 Phase - Minimum Vacuum Required 24.0 –in. Hg

Onboard Electric
Generator

110 volt -

2800 Watt (Continuous)

110 volt -