Easi-cladder™ plus – JLG Easi-Cladder User Manual

Page 27

Advertising
background image

EASI-CLADDER™ PLUS

3128112

– JLG Accessory Manual –

19

Wall Panel Removal From An Existing Wall

1.

Follow machine power up steps 1 through 4.

NOTE: Extend the platform extension ends to accommodate wall panel length,

if necessary.

2.

Position and raise the platform to the desired height to remove the
panel.

3.

Extend and set the platform stabilizer pads out from the side of the
machine platform against the panel below the one being removed.
(See Figure 8.)

NOTE: This will limit platform side to side movement once the wall panel is

lifted over the side of the platform.

4.

Push the VACUUM ON switch, on the control box, to start the vacuum
pump. (See Figure 6., Item 3)

NOTE: The vacuum pump is rated for continuous operation. Once turned on

the pump will not shut off until the machine is powered down.

5.

Lift and pull the vacuum release switch back (Figure 6., Item 3) while
raising the lift arm to vertical (Figure 6., Item 4).

6.

Fully retract the lift arm. (Figure 6., Item 6)

7.

Telescope the lift arm out against the panel until the suction cups make
contact with the panel. The GREEN light will be on when a proper vac-
uum is achieved in the system.

8.

Once vacuum is achieved, unscrew panel from the wall.

9.

Lift panel with control box switch (Figure 6., Item 6), then telescope in
(Figure 6., Item 5), and lift panel down (Figure 6., Item 4) onto panel
load rails.

10.

To release the panel, follow steps 15 through 17 in "Releasing Panel"
shown in previous sub-section.

STORAGE

KEEP THE VACUUM MANIFOLD CUPS COVERED WHEN MACHINE IS NOT IN USE.

Advertising
This manual is related to the following products: