Platform Will Not Lower Using Platform Control

Overview Of Procedure

This procedure tests for ground coming out of the MC-1 box to the dump valve circuit and through to the ground control tog-
gle switch.

Check For These Obvious Conditions First:

• Battery voltage 24 volts. (Fully charge batteries)

• Hydraulic oil is within it’s specified operating temperature range.

Table 3-23. Platform Will Not Lower Using Platform Control.

STEP

ACTION

SPEC

YES

NO

1.

Will machine lower manually, using the manual descent knob?

Go to Step 2

See (Table 3-26)

2.

Will machine lower from ground control switch?
Note: Key switch must be set to GRND to check this.

Go to Step 3

See (Table 3-23)

3.

Check for ground on the Tan, 4-1 wire at the MC-1 box, X105 con-
nector, pin 6.

Go to Step 4

Repair/Replace

Joystick/

MC-1 Box

4.

Check for ground on the Tan, 4-1 wire at the lift down coil.

Go to Step 5

Replace/Repair

Wire or

Connection

5.

Check complete pump motor circuit . (See Table 3-21)