SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROLS

3120860

– JLG Lift –

3-9

3.

Rotate. (35/n35/40/n40/45 electric)

A three position ROTATE control switch permits rota-
tion of the platform when positioned to left or right.

4.

Platform Leveling Override.
(35/n35/40/n40/45 electric)

A three position LEVEL control switch allows the
operator to compensate for any difference in the
automatic self leveling system by positioning the
control switch to UP or DOWN.

5.

Lower Boom Lift.

Provides for raising and lowering of Lower Boom
and (Mid Boom on 40/n40/45 electric) when posi-
tioned to UP or DOWN.

6.

Upper Boom Lift.

Provides for raising and lowering of Upper
Boom when positioned to UP or DOWN.

7.

Telescope. (35/n35/40/n40/45 electric)

Provides for extension and retraction of Upper Boom
when positioned to IN or OUT.

8.

Swing.

The SWING control switch provides 360 degrees
non-continuous turntable rotation. To activate
SWING, position switch to LEFT or RIGHT.

9.

Circuit Breakers.
(March 1995 to Present)

The circuit breakers open (pop out) to indicate a
short or overload somewhere on the machine.

10.

Battery Indicator and Hourmeter .

An hourmeter, installed in the upper portion of the
Ground Control Box, registers the amount of
machine operating time. The hourmeter registers up
to 9,999.9 hours and cannot be reset.

Figure 3-3. Ground Control Station, 30 electric (Sheet 1 of 2)