SECTION 1 - SAFETY PRECAUTIONS

1-2

– JLG Lift –

3120860

1.3

ELECTROCUTION HAZARD.

Table

Minimum safe approach distances (M.S.A.D.) to energized (exposed or insulated) power lines and parts.

Table 1-1.

Minimum safe approach distance (M.S.A.D.) to energized

(exposed or insulated) power lines and parts.

VOLTAGE RANGE

(Phase to Phase)

MINIMUM SAFE APPROACH DISTANCE

Feet (Meters)

0 to 300V

AVOID CONTACT

Over 300V to 50KV

10

(3)

Over 50KV to 200KV

15

(5)

Over 200KV to 350KV

20

(6)

Over 350KV to 500KV

25

(8)

Over 500KV to 750KV

35

(11)

Over 750KV to 1000KV

45

(14)

DANGER: DO NOT maneuver machine or personnel inside PROHIBITED ZONE.
ASSUME all electrical parts and wiring are ENERGIZED unless known otherwise.