SECTION 1 - SAFETY PRECAUTIONS

3121162

– JLG Lift –

1-3

Electrocution Hazards

• This machine is not insulated and does not provide pro-

tection from contact or proximity to electrical current.

• Maintain safe distance from electrical lines, apparatus,

or any energized (exposed or insulated) parts in accor-
dance with the Minimum Safe Approach Distance
(MSAD) as specified in Table 1-1.

• Allow for machine movement and electrical line sway-

ing.

DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIB-
ITED ZONE (MSAD)
. ASSUME ALL ELECTRICAL PARTS AND
WIRING ARE ENERGIZED UNLESS KNOWN OTHERWISE.

Tipping Hazards

• If equipped, lock the right rear (gate side) caster wheel

parallel with the base frame before pushing machine
onto a slope.

• Do not elevate platform while on a slope, or on an

uneven or soft surface.

• Before pushing on floors, bridges, trucks, and other sur-

faces, check allowable capacity of the surfaces.

• Never exceed the maximum platform capacity. Distrib-

ute loads evenly on the platform and material tray.

• Keep the chassis of the machine a minimum of 2 ft.

(0.6m) from holes, bumps, drop-offs, obstructions,
debris, concealed holes, and other potential hazards at
the ground level.

• Never attempt to use the machine as a crane. Do not

tie-off machine to any adjacent structure.

• Do not increase the platform or material tray size with

unauthorized deck extensions or attachments.

• If mast assembly or platform is caught so that one or

more wheels are off the ground, the operator must be
removed before attempting to free the machine. Use
cranes, forklift trucks, or other appropriate equipment to
stabilize machine and remove personnel.

Table 1-1.Minimum Safe Approach Distance

VOLTAGE RANGE

(PHASE TO PHASE)

MINIMUM SAFE DISTANCE -

Feet [m]

0-300V

Avoid Contact

Over 300V to 50KV

10 ft. [3 m]

Over 50KV to 200KV

15 ft. [4.6 m]

Over 200KV to 350KV

20 ft. [6 m]

Over 350KV to 500KV

25 ft. [7.6 m]

Over 500KV to 750KV

35 ft. [10.6 m]

Over 750KV to 1000KV

45 ft. [13.7 m]