SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

3-4

– JLG Lift –

3121162

Bubble Level Indicator

Floor Stop Operation

NOTE: The floor stop must be SET before the platform can

be elevated. When SET, the floor stop relieves the
right front caster wheel of the machines weight so
the machine does not roll in any direction.

IF FLOOR STOP IS NOT OPERATING PROPERLY, DO NOT ATTEMPT
TO ELEVATE THE PLATFORM.

Platform Manual Descent Control Valve

The manual descent control valve allows lowering of the
platform in the event that the platform operator cannot
lower the platform after elevating to the desired level. This
control is to be used in instances such as, a loss of
machine power (battery discharged), a machine malfunc-
tion, or the operator is incapacitated in some way.

ALWAYS LOOK AT AREA UNDER PLATFORM BEFORE AND DURING
PLATFORM LOWERING, FOR OBSTRUCTIONS OR PERSONNEL.

When bubble is inside
center black ring, machine
is LEVEL.

DO NOT elevate platform
unless machine is level.

TO SET

PRESS DOWN on
the pedal locking it
in the down pos-
tion.

TO RELEASE

PUSH on the
RELEASE ROD at
the rear of the
pedal.

TO LOWER
PLATFORM

Pull out on
knob.

TO STOP
LOWERING

Release knob.
(spring loaded)