SECTION 3 - CHASSIS & TURNTABLE

3121198

– JLG Lift –

3-65

3. If the board has been replaced or the tilt sensor is

not calibrated, connect an analyzer to the machine
at the ground control console and calibrate tilt sen-
sor. Enter Level 2 in Analyzer and use the right arrow

key

to scroll to Calibrations. Next use the down

arrow

to reach TILT SENSOR. Then press the

ENTER key

.

4. Deploy the outriggers until the machine auto levels.

The machine will indicate it has leveled by beeping
three times and flashing the outrigger indicator lights
on the ground control box.

5. Verify the machine is level using a digital level as

shown in step 1. If not level within 0.5° in each direc-
tion, continue to Setup When Machine Is Not on
Firm Level Surface and Adjustment Procedure.

NOTE: The tilt sensor reading may be accessed through the

analyzer: Use the right arrow key

to reach

DIAGNOSTICS, down arrow key once

, right

arrow key

to scroll over to SYSTEM, then the

down arrow key

to reach Tilt

Setup When Machine Is Not on Firm Level

Surface and Adjustment Procedure:

1. Connect an analyzer to the machine at the ground

control console. Turn the machine power on and
select the ground control mode. Go to service mode
and adjust outriggers individually to level the
machine:

a. On the analyzer, select "ACCESS LEVEL 2" and

enter 33271. Use the right arrow key

to

scroll to CALIBRATIONS. Press the ENTER key

. Press the right arrow key

once to

reach AUTOLEVEL, then the down arrow key

once to reach OVERRIDE F-L

b. Arrow down

until you reach the desired

outrigger. Use the outrigger deploy switch on
the Ground control to raise or lower the outrig-
ger.

2. Verify the reading from digital level. Must not exceed

0.2° in both the X- direction (left Wheel to right
wheel) and Y-direction (tongue to tail lights)

3. Calibrate tilt sensor. Enter Level 2 in Analyzer and

use the right arrow key

to scroll to CALIBRA-

TIONS. Press the down arrow key

once to

reach TILT SENSOR. Then hit ENTER

.

4. Recycle emergency stop switch. Retract leveling

jacks until the set lights go out. Set leveling jacks
and wait until the machine signals it is level. Verify
machine auto levels within 1.0°