Table 6-2. Machine Model Adjustments and Speeds - ANSI & CSA

FUNCTION

ADJUSTMENT

1,4

MODEL DEFAULTS

MODEL TIME RANGE (SECONDS)

2,3

RANGES

5

T350

Electric

T350 Gas

T500J

Electric

T500J

Gas

T350

Electric

T350 Gas

T500J

Electric

T500J Gas

DRIVE

FORWARD

(25’ COURSE)

20-28

19-22

20-28

19-22

REVERSE

(25’ COURSE)

20-28

19-22

20-28

19-22

ACCEL

0.1 to 5.0 sec

1.0

1.0

1.0

1.0

DECEL

0.1 to 3.0 sec

0.5

0.5

0.5

0.5

L FWD MIN

0 to 100%

15

15

15

15

L FWD MAX

0 to 100%

50

50

50

50

L REV MIN

0 to 100%

15

15

15

15

L REV MAX

0 to 100%

50

50

50

50

R FWD MIN

0 to 100%

15

15

15

15

R FWD MAX

0 to 100%

50

50

50

50

R REV MIN

0 to 100%

15

15

15

15

R REV MAX

0 to 100%

50

50

50

50

LIFT

ACCEL

0.1 to 5.0 sec

1.5

1.5

2.5

2.5

DECEL

0.1 to 3.0 sec

0.8

0.8

0.8

0.8

MIN UP

0 to 25% (75%)

6

56

3

56

MAX UP

0 to 100% (85%)

80

72

80

72

24-34

24-34

40-50

40-50

MIN DOWN

0 to 25% (50%)

11

25

14

25

MAX DOWN

0 to 35% (65%)

27

46

26

46

26-36

26-36

35-46

35-46

CREEP

0 to 50%

50

50

50

50

SWING

ACCEL

0.1 to 5.0 sec

2.7

2.7

2.7

2.7

DECEL

0.1 to 3.0 sec

1.0

1.0

1.0

1.0

MIN LEFT

0 to 25% (75%)

4

58

4

50

MAX LEFT

0 to 50% (85%)

35

63

35

63

55-85

55-85

65-105

65-105

MIN RIGHT

0 to 25% (75%)

4

58

4

50

MAX RIGHT

0 to 50% (85%)

35

63

35

63

55-85

55-85

65-105

65-105

CREEP

0 to 35%

30

30

30

30

TELESCOPE

ACCEL

0.1 to 5.0 sec

1.5

1.5

1.5

1.5

DECEL

0.1 to 3.0 sec

0.8

0.8

0.8

0.8

MIN IN

0 to 25% (75%)

5

57

1

57

MAX IN

0 to 100% (85%)

100

80

80

72

17-23

15-21

19-26

19-26

MIN OUT

0 to 25% (75%)

10

60

10

60

MAX OUT

0 to 100% (85%)

60

80

100

80

17-23

13-19

19-26

19-26

CREEP

0 to 35%

30

30

30

30

Advertising