31200745

4. Verify operation with no objects in detection zone. No audible alarm.

5. Verify operation when object is in range of approximately 9 to 15 ft (2.7 to 4.5 m).

Produces pulsing audible alarm at a frequency of one per second (1 Hz).

6. Verify operation when object is in range of approximately 7 to 9 ft (2.1 to 2.7 m).

Produces pulsing audible alarm. Produces pulsing audible alarm at a frequency
of two per second (2 Hz).

7. Verify operation when object is range of approximately 5 to 7 ft (1.5 to 2.1 m)

Produces pulsing audible alarm at a frequency of four per second (4 Hz).

8. Verify operation when object is under approximately 5 ft (1.5 m) from machine.

Produces pulsing audible alarm at a frequency of eight per second (8 Hz).