Shutdown procedure, Shutdown procedure -5 – JLG 460SJ Operator Manual User Manual

Page 63

Advertising
background image

SECTION 4 - MACHINE OPERATION

3121216

– JLG Lift –

4-5

6.

Turn key of SELECT switch to PLATFORM.

7.

From Platform position POWER/EMERGENCY STOP switch
to ON, then push the ENGINE START switch to the forward
position until engine starts.

NOTE:

Footswitch must be in released (up) position before starter will
operate. If starter operates with footswitch in the depressed
position, DO NOT OPERATE MACHINE.

Shutdown Procedure

IF AN ENGINE MALFUNCTION NECESSITATES UNSCHEDULED SHUTDOWN, DETERMINE
AND CORRECT CAUSE BEFORE RESUMING ANY OPERATION.

1.

Remove all load and allow engine to operate at low speed
setting for 3-5 minutes; this allows for further reduction of
internal engine temperature.

2.

Position POWER/EMERGENCY STOP switch to OFF.

3.

Turn key of MASTER switch to OFF position.

NOTE:

Refer to Engine Manufacturer’s manual for detailed informa-
tion.

Advertising
This manual is related to the following products: