SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

3121216

– JLG Lift –

6-29

3.

Wheel Drive Hub

Lube Point(s) - Level/Fill Plug
Capacity - 17 oz (0.5 L) - 1/2 Full
Lube - EPGL
Interval - Check level every 3 months or 150 hours of opera-

tion; change every 2 years or 1200 hours of operation

4.

Hydraulic Return Filter

Interval - Change after first 50 hours and every 6 months or

300 hours thereafter or whenever Charge Filter is replaced

5.

Hydraulic Charge Filter

Interval - Change after first 50 hours and every 6 months or

300 hours thereafter or as indicated by Condition Indicator

6.

Hydraulic Tank

Lube Point(s) - Fill Cap
Capacity - 40.0 gal tank (151L) 52.0 gal system (196.8L)
Lube - HO
Interval - Check Level daily; Change every 2 years or 1200

hours of operation