SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

6-30

– JLG Lift –

3121216

7.

Suction Strainers

Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation, remove

and clean at time of hydraulic oil change

8.

Oil Change w/Filter - Caterpillar

Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N 7026855)
Capacity - 10 qt (9.4 L)
Lube - EO
Interval - Every Year or 500 hours of operation
Comments - Check level daily/Change in accordance with

engine manual

9.

Oil Change w/Filter - Deutz D2011

Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N 7016331)
Capacity - 6.3 qt (5.9 L) engine only
Lube - EO
Interval - Every Year or 1200 hours of operation

Comments - Check level daily/Change in accordance with
engine manual