SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
6-30
– JLG Lift –
3121216
7.
Suction Strainers
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation, remove
and clean at time of hydraulic oil change
8.
Oil Change w/Filter - Caterpillar
Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N 7026855)
Capacity - 10 qt (9.4 L)
Lube - EO
Interval - Every Year or 500 hours of operation
Comments - Check level daily/Change in accordance with
engine manual
9.
Oil Change w/Filter - Deutz D2011
Lube Point(s) - Fill Cap/Spin-on Element (JLG P/N 7016331)
Capacity - 6.3 qt (5.9 L) engine only
Lube - EO
Interval - Every Year or 1200 hours of operation
Comments - Check level daily/Change in accordance with
engine manual