Section 3 - Controls and Indicators

3-15

3128447

Right Panel

2. Boom Ride Control Switch: Depress switch to activate boom ride control. Blue

indicator light on switch flashes and slight boom movement may occur as
system engages. Indicator then illuminates to indicate boom ride control is
active. While activated and traveling, the system acts to cushion boom
movement. Depress switch again to deactivate boom ride control.

Note: If boom is raised above 8 degrees or extended more than 3 ft (0,9 m),
Boom Ride Control is disabled.

3. AccuPlace Fault Reset Indicator: Flashes orange when fault occurs while in

AccuPlace mode. Depress switch to acknowledge fault and continue operation.

4. AccuPlace Mode Indicator: Illuminates green when machine is in AccuPlace

mode. Flashes to indicate a cylinder has reached mechanical limitations and
AccuPlace movement is no longer coordinated. When coordinated movement is
possible again, AccuPlace indicator stops flashing.

5. Beacon Light Switch (if equipped): On/Off switch.

6. Windshield Wiper and Washer Switch (if equipped): Two speed rotary switch.

Depress to activate washer. Return to first position to turn off wiper.

7. Work Light Switch (if equipped): On/Off switch.

OY1301