SECTION 2 - SERVICE PROCEDURES - LOAD SENSING SYSTEM

2-2

– JLG Lift –

3124289

2.2 LSS - SETUP AND ADJUSTMENT

Procedure Overview (All Vertical Lifts)

The mechanical portion of the LSS system requires three
(3) adjustments to operate properly.

Platform Crossmember/Coil Spring Pre-load Height

Adjustment; sets the coil spring pre-load between the
platform and mast crossmember with no load in the
platform.

Mast Header Crossmember Positive Stop Adjust-

ment; sets the maximum amount of downward travel of
the platform, if the platform is overloaded.

LSS Overload Actuator Adjustment; sets the actuator

to trip the LSS limit switch, signaling an overload situa-
tion, when the platform is overloaded. There is a three
(3) second delay between switch opening and warning
activation.

THESE SETUP PROCEDURES WILL REQUIRE ACCURATELY
MEASURED WEIGHT UP TO AND OF A PERCENTAGE OVER THE
PLATFORM’S MAXIMUM CAPACITY. SEE TABLE 2-1
IN THE FOL-
LOWING SUB-SECTION.

Figure 2-2. Load Sensing System - Indicators

(Drivable Vertical Lifts)

1. Ground Control Module 3. LSS Warning Lamp
2. LSS Warning Decal

4. LSS Warning Alarm

Figure 2-3. Platform Console LED Indicators

(Drivable Vertical Lifts)

1. The platform console LED bar will flash 9 (Nine) LEDs

to indicate a Platform Overload condition.

–+

Figure 2-4. LSS Component Adjustments

1. Coil Spring Pre-Load Height Adjustment
2. Crossmember Positive Stop Adjustment
3. Overload Actuator Adjustment

Notes: Shown with manual storage box removed and
with little or no load in the platform.