SECTION 2 - SERVICE PROCEDURES - LOAD SENSING SYSTEM

2-8

– JLG Lift –

3124289

2.5 GROUND CONTROL MODULE

(DRIVABLE VERTICAL LIFTS ONLY)

The following instructions are supplemental to the DVL/
DVSP Operators and Service manuals and show addi-
tional features on the ground control module for machines
equipped with the Load Sensing System.

Programming

The Ground Control Module must be programmed to
detect the Load Sensing System before the LSS will func-
tion properly.

1. Enter the Service Programming Mode (Level 2 -

Password) at the Ground Control Module (Refer to
the machine’s Service Manual for instructions)
.

2. Enter the Program menu and scroll through the item

list to find and set the LSS programming item range
as shown following:

LCD Display

When an overload warning is detected the following alter-
nating screens are displayed on the Ground Control Mod-
ule LCD screen:

2.6 PLATFORM CONTROL CONSOLE

(DRIVABLE VERTICAL LIFTS ONLY)

Table 2-3. Ground Control Module Programming -

Drivable Lifts ONLY.

PROGRAMMABLE

ITEM

FACTORY

PRESET

SETTING RANGE

Enable Detection of
LSS

2

0 - Detection Disabled
1 - Enabled - Warning Disables

Platform Functions Only

2 - Enabled - Warning Disables

Platform and Ground

Control Functions

LCD Display Symbols

1. Drive and Lift Up/Down Functions - Disable Indicators
2. Description of Warning - Platform Overloaded

Note: When the Overload condition is indicated the LCD screen will

alternate between the text and symbol display modes.

00000.0

1

2

Platform Console LED Indicators

1. The platform console LED bar will flash 9 (Nine) LEDs

to indicate a Platform Overload condition.

–+