AirLive ES-4000 v2 User Manual
Page 157
![background image](/manuals/553875/157/background.png)
Example:
To Deploy a High Availability Environment
Step1
Power off and deploy Master and Backup ES-4000V2, connect both port1 to switch.
(Figure 10-1)
Step2
Connect Master ES-4000V2 port 2 (HA port) to Backup ES-4000V2 port 2.
Step3
Don’t power on Backup ES-4000V2 before you finish the configuration of Master ES-4000V2.
Step4
Change interface IP address of Master ES-4000V2 to differ with default IP 192.168.1.1, ex.
192.168.1.2 (Figure 10-2)
Step5
Change Management IP of Master ES-4000V2 to differ with default IP 192.168.2.1, ex.
192.168.2.2. (Figure 10-3)
Step6
Make sure the Master ES-4000V2 and Backup ES-4000V2 port 1 and port 2 are connected
properly.
Step7
Power on the Backup ES-4000V2, then both ES-4000V2 will synchronize data and setting.
(Figure 10-4, 10-5)
Step8
It needs to take 10 hours to synchronize the data and setting. (Figure 10-6)
ES-4000 Master
IP:192.168.1.2
HA IP:192.168.2.2
ES-4000 Backup
IP:192.168.1.1
HA IP:192.168.2.1
Port 1(Mail Port)
Port 1(Mail Port)
Port 2(HA Port)
Figure 10-1 The Master device deployment under High Availability mode
153