Operation
MODE
DESCRIPTION
PARAMETERS
1
Units
Range = 0-2
Default = 0
0 = feet
1 = inches
2 = mm
Mode 1 is used to select the units of measurement that will be used
throughout the setup process and also for display. The units will also
determine the resolution of the display and the outputs. The resolution is: feet
0.01, inches 0.1 and millimeters 1.
NOTE: All modes must be set using the units selected in Mode 1.
MODE
DESCRIPTION
PARAMETERS
2
4 mA distance
Units = Mode 1
Range = 0-9999
Default = 1.00 ft.
Mode 2 sets the 4 mA distance.
MODE
DESCRIPTION
PARAMETERS
3
20 mA distance
Units = Mode 1
Range = 0-9999
Default = 25.00 ft.
Mode 3 sets the 20 mA distance.
Zero Point
Max. Distance
Zero Point
Max. Distance
mode 11
mode 12
mode 11
mode 12
20 ma
4 ma
4 ma