• Sensitivity

The sensitivity can be adjusted by using the sensitivity switch and by

adjusting the voltage.

H with 4.5~5.5 VDC: for highly fluidized materials.
L with 2.0~3.0 VDC: for light materials.
L with 4.5~5.5 VDC: standard adjustment (bulk density 0.2/cm

3

or more)

L with 6.0~7.0 VDC: for sticky materials.

Set the sensitivity switch to AJ.
Turn sensitivity volume until the desired voltage is read.

After adjustment, set the switch to H or L and make sure 8~10 VDC can be

read.