VBL Series

17

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

• Wiring

Wiring should be in accordance with all local codes. Control cable should be a

minimum of 0.75 mm

2

.

• Contact capacity

240 V 3 A AC (Resistive)
30 V 3 A DC (Resistive)

• Power supply

90 to 132 V AC 50/60 Hz
180 to 264 V AC 50/60 Hz

• Power consumption

5 VA

Caution: Make sure the

supply voltage matches the
markings on the circuit board
terminals. Applying the wrong
voltage or miswiring will
damage the sensor and may
cause injury.

• Start Up

1.

Test Points
For fine adjustment of the
sensitivity.

2.

Sensitivity Switch
To set high or low
sensitivity.

3.

Sensitivity Volume
To adjust the sensitivity.

4.

Detection Status LED

5.

Power Status LED