Maintenance, 1 maintenance device – Autoquip SUPER TITAN DOUBLE LONG User Manual
Page 31
 
31
6. MAINTENANCE
6.1 Maintenance Device
 
 
NEVER go under a raised lift platform until load is removed and 
lift is securely blocked in raised position with maintenance 
device. 
 
Lock-out/tag-out power source. 
 
 
This procedure describes the only factory-approved method of working under a lift. Follow these 
instructions EVERY time you plan to reach or crawl beneath the lift to perform service or maintenance – 
no matter how momentary that might be. 
 
If the factory-provided maintenance leg is damaged or missing, stop immediately and consult the factory 
for assistance. The manufacturer is not liable for your failure to use the approved maintenance leg and 
procedures that have been provided. 
 
1. All loads must be removed from the lift prior to engaging the maintenance leg. The maintenance leg 
is designed to support an unloaded lift only. Failure to remove the load from the lift prior to blocking 
could cause the failure of the maintenance leg and allow the lift to fall unexpectedly. This can result in 
personal injury or death. 
 
2. Raise the lift to its fully raised position. If you do not, the maintenance leg may not be able to be 
placed properly in the designed blocking position.
 
3. The lift will be provided with one (1) maintenance leg, stored on the outside of the base frame. The 
leg must be securely inserted into the leg sockets on top frame and bottom frame of lift (See Figure 
6.1). 
 
4. Lower the lift platform until the leg is fully seated in both sockets. Re-check to ensure leg is fully and 
properly engaged in both sockets. If leg is not fully engaged, the lift could fall unexpectedly.
^ WARNING