3 general maintenance, Notice – Autoquip SUPER TITAN DOUBLE LONG User Manual
Page 35
 
35
6.2.5 Oil Capacity
Oil capacity varies between models. Capacity is a minimum 10 gallons. 
 
Use approved fluids only. Use of unauthorized fluids may cause damage 
to seals and hosing. 
 
Do Not Use: 
 Automatic Transmission Fluid (ATF)
 Hydraulic Jack Oil 
 Hydraulic 
Fluids
 Brake
Fluids
6.3 General Maintenance
6.3.1 Hydraulic Cylinder Repair
6.3.1.1. Cylinder Plunger Removal
1. Raise lift to its full height and engage
maintenance devices. See “Maintenance 
Devices”. 
 
2. Disconnect electrical power to lift. Follow lock 
out-tag out procedure.
3. Disconnect cylinder hose at power unit end and
insert into reservoir oil-fill hole.
 
4. Remove thrust angle clips (A) from ram end of 
cylinder and force ram slowly back to its fully 
closed position to push oil back into reservoir. 
 
5. Remove cylinder hose from reservoir fill hole and 
pull ram (B) all of the way out of cylinder. Support 
it carefully so that it does not drop when it clears 
cylinder end. Lay it down in a safe, clean place. 
Some oil may drip from the end of cylinder so 
have waste cloth or paper beneath lift to protect 
floor. 
 
 
 
 
 
 
 
 
 
 
NOTICE