Autoquip SUPER TITAN DOUBLE LONG User Manual
Page 48
 
48
 
 
 
 
PROBLEM
POSSIBLE CAUSE AND SOLUTION
Lift Seems Bouncy During 
Operation.
Lower lift to collapsed position and continue to hold “DOWN” button an 
additional 10-30 seconds to bleed air from cylinder. Do not confuse 
spongy or jerky operation with small surges that may occur when 
operating on rough or uneven floors. 
 
Check for oil starvation. 
Motor Labors Or Heats 
Excessively. 
 
Voltage may be low. Check voltage at motor terminals while pump is 
running under load, not at line source or while pump is idling. 
Inadequate wiring can starve motor even when source voltage is ample. 
 
Most of Autoquip’s standard motors are rated for intermittent duty. If a 
single-phase motor is being run more than 15 – 20 motor starts per 
hour, or a 3-phase motor more than 200 starts per hour, the problem 
may be motor over-heating. 
 
Running against relief pressure unnecessarily due to over loaded lift or 
hitting physical stops. 
 
Failure to observe wiring diagram on nameplate for proper voltage 
connections. 
 
Pump may be binding from oil starvation, which develops high internal 
heat. Check for low oil level or clogged breather holes in reservoir fill 
plug. Pump can be damaged by oil starvation.