27

1. Arrow on hydraulic velocity fuse indicates direction

of oil flow restriction. Hydraulic velocity fuse must
be installed with arrow pointing away from cylinder.

Do not use Teflon tape on hydraulic
threaded connections. Tape
fragments may damage hydraulic
system.

2. Apply Loctite PST #567 pipe thread sealant or equivalent to threads and install fuse to cylinder with

arrow pointing away from cylinder. Tighten fuse.

3. Fill reservoir to full mark if necessary with proper oil.

4. Check all fitting connections for hydraulic leaks and tighten as necessary.

5. Bleed air from system. See “Bleeding Air From System” in this section.


6.3.4 Hose Orientation

To prevent damage to cylinder hoses, it is necessary to establish a correct hose shape and pattern of
movement as follows:

1. Raise lift to its full height and block securely. See “Maintenance Devices”.

2. Install one end of new hose to cylinder fitting.

3. Since hose is fixed at both ends, it is possible to put a twist in hose that will allow it to describe the

same pattern each time lift is operated. This twist will allow hose to travel about half way between
cylinder on right side and inner leg on right side.

4. Lower lift carefully and verify hose is free and clear of cylinder and inner leg assembly. If not, twist

hose in direction necessary to clear any obstruction and tighten swivel fitting.