PROBLEM

POSSIBLE CAUSE AND SOLUTION

Lift Does Not Raise,
Continued.

Breather holes in reservoir fill plug may be clogged. Remove and clean.

Voltage may be too low to run pump with existing load. Check by
measuring voltage at motor terminals, or as near as possible, while
pump is running under load.

Inadequate or incorrect wiring can starve

motor when source voltage is ample. Correct as necessary.

Down valve may be energized by faulty wiring or stuck open. Remove
solenoid and check.

Motor may be single phasing. Check wiring, fuses, etc.

Pump may be seized if motor is humming or blowing fuses on overload
protection devices. Remove pump. Pump can be rotated by hand
unless seized. Check for cracks in housing.

Down solenoid valve stem may be bent, causing valve to stick open.
Replace down solenoid valve.

PROBLEM

POSSIBLE CAUSE AND SOLUTION

Lift Won’t Lower.

Solenoid coil may be incorrectly wired, burned out, not rated for the
voltage, or line voltage may be excessively low. Check voltage near
coil.

Velocity fuse may be locked. Do not attempt to remove the velocity
fuse. The following steps should be followed:

1. Remove load from lift. Inspect all fittings, hoses, and other hydraulic
components for leads or damage.

2. If no leak or damage is noticed, attempt to pressurize lifting cylinder
by pressing “UP” button on controller for a few seconds. Immediately
release “UP” button and press “DOWN” button. If lift starts to lower,
continue pressing “DOWN” button until lift is fully lowered.

3. If lift does not lower after trying Step 2, wait approximately 10 – 15
minutes for pressure in hydraulic system to equalize. Then, press
“DOWN” button until lift is fully lowered.

4. Once lift is fully lowered, hold “DOWN” button for approximately 60
seconds to bleed air from system. This step may need to be repeated
several times to fully remove air in system by raising the lift to 50% of
its travel and lowering.

If above steps do not correct problem, contact Autoquip to obtain
instruction for further action.