Page 17: Remote power unit installation

Advertising
background image

17

Lock-out/tag-out power source.

Base frame of lift has pre-drilled holes for anchoring floor. Anchor lift to floor. Lifts with oversize platforms

have minimum pull out requirements of 2,000 lbs. for each anchor. See “Shimming And Anchoring Lift To
Concrete”.


Make permanent electrical and hydraulic connections and operate lift through a few cycles.

Clean up debris and spilled oil from area. Dispose of oil in an environmentally safe manner.

Touch-up paint is available from Autoquip for repair of damaged paint surfaces.

Train personnel on lift operation, all safety features and procedures.


4.2 Shimming And Anchoring Lift To Concrete

Recommended concrete anchor bolts are: HILTI “Kwik-Bolt”, Molly Parabolt or similar.

Verify lift is positioned correctly.

Drill holes in concrete as specified by anchor bolt manufacturer.

Install and tighten anchors as specified by anchor bolt

manufacturer.


After lift has been aligned, leveled and shimmed, and anchors

have been installed, pour grout under entire base frame.


When grout has set and cured, tighten nuts on anchor bolts.

Route hydraulic hose or electrical cord through conduit in pit wall.



4.3 Remote Power Unit Installation

The remote power unit is to be located in an area protected from the elements and should be installed

prior to the lift to facilitate lift operation during installation into the pit.


The remote contractor power unit is equipped with power unit mounting brackets and can be wall or floor

mounted using these brackets. If equipped with a vertical power unit, optional power unit mounting
brackets must be used for wall mounting.


The electrical work is to be done in accordance with local codes by a qualified electrician. See the

“Maintenance” section for the standard wiring diagram.


If permanent electrical work is not complete, some means of temporary power with an on/off device for the

motor will be required.


Fill the reservoir with oil per instructions in the "Maintenance” section.

Advertising