4 power unit wiring, 1 intermittent duty remote power units, 2 heavy duty remote power unit – Autoquip TORKLIFT T2 DOUBLE PANTOGRAPH User Manual

Page 18: Power unit wiring, Intermittent duty remote power units, Heavy duty remote power unit

Advertising
background image

18

4.4 Power Unit Wiring




MOTOR

5

4

6

CONNECT TO LINE

CONNECT TO LINE

7

1

3

9

2 8

3

2

1

9

6

4

7

5 8

J
J

J
J

THERMOSTATS

OPTIONAL

MOTOR

THERMOSTATS

OPTIONAL

208/230VAC

460VAC

3 PHASE




4.4.1 Intermittent Duty Remote Power Units

1. The Intermittent Duty Power Units utilize a 1-½ or 5 HP / 208-230-460 Volt / 60 hertz / 3 phase “Super-

Torque” intermittent duty motor with (one full lift cycle per 2 minute period)

driving a high pressure

positive displacement pump assembly with an internal relief valve, check valve and down solenoid
valve.

2. Because an Autoquip "Super-Torque" motor actually delivers substantially more horsepower than the

nameplate rating, it must always be wired for heavier current-draw than standard motors of the same
nameplate rating. However, because of the "Super-Torque" motor’s starting efficiency and superior
running characteristics, circuit components do not have to be as large as for standard motors of equal
delivered horsepower.



4.4.2 Heavy Duty Remote Power Unit

1. The Vertical 'HD' Power unit utilizes a 5 HP/ 208-230-460 Volt / 60 hertz / 3 phase Heavy Duty motor,

(with a 30 minute continuous duty rating). The power unit is coupled with a high-pressure positive
displacement gear pump, and Autoquip Corporation’s patented Deltatrol valve assembly.


2. The motor connection diagram should be referenced in connecting the motors to a power source.

Remember that heavy wire must be used all the way to the power source.

HP and Voltage

Full Load Amperages

1-½ HP: 60 CY / 3 PH

Intermittent Duty Motor

208 V= 4.8 Amps

230 V=4.6 Amps

460 V= 2.3 Amps

5 HP: 60 CY / 3 PH

Intermittent Duty Motor

208 V=15.8 Amps

230 V=14.8 Amps

460 Volts = 7.4 Amps

5 HP: 60 CY / 3 PH

Heavy Duty Motor

208 V=16 Amps

230 V=15.2 Amps

460 V=7.6 Amps

5 HP motors

1-½ HP motor

Advertising