6.2 Routine Maintenance

Prevent serious injury or death.


Lock-out/tag-out power source prior to any maintenance being performed.

Prevent serious injury or death.


Never go under lift platform until load is removed and scissors
mechanism is securely blocked in raised position with
maintenance devices.

See Maintenance Devices section.

Pressurized fluids can penetrate the skin.

Hydraulic hoses can fail from age, damage and exposure.
Do not search for hydraulic leaks without body and face protection. A tiny,
almost invisible leak can penetrate the skin, requiring immediate medical
attention.

Use wood or cardboard to detect hydraulic leaks, never your hands.

Spilled hydraulic fluid is slippery and may also present a fire
hazard.

Clean up spilled hydraulic fluid.


Normally, scissor lifts will require very little maintenance. However, a routine maintenance program could
prevent costly replacement of parts and/or downtime.

6.2.1

Every Day Or 10 Hours Of Operation

• Check reservoir fluid level.

• Check for fluid leaks.

• Check all hoses and electrical cords for cracks, abrasions, twisting, etc. Small leaks at connections

can be remedied by tightening connections or replacing faulty component.

• Check that oil pressure does not exceed 2,000 psi.

• Check all pivot joints & roller bearings for noise and wear.

• Check overall condition of unit (i.e. bends, breaks, loose or missing screws, etc.).