LIFT BLOCKING INSTRUCTIONS

DANGER !

If for any reason you are unable to lower the lift completely onto
the maintenance device(s), stop immediately and consult the
factory. Failure to properly use the factory approved maintenance
device(s) could result in severe injury or death.


5. Once the maintenance devices are properly and securely engaged, continue to

press the down button, valve or switch for an additional 5-10 seconds to
relieve all pressure in the hydraulic system (it could take longer in a pneumatic
system).

WARNING !


Failure to relieve operating system pressure could result in the
sudden and unexpected release of high-pressure fluids (or air)
during maintenance and/or repair of the lift and result in severe
injury or death.

6. Follow OSHA electrical lock-out/tag-out procedures. Disconnect and tag all

electrical and/or other power sources to prevent an unplanned or unexpected
actuation of the lift.

7. Once inspection or work is complete, reverse the performance of the steps

above to raise the lift off the maintenance devices and flip the devices back
into their designated storage positions outside the base frame.

DANGER !

HIGH VOLTAGE!! Disconnect and/or lock out the electrical
supply to the power unit per OSHA regulations prior to any
installation or maintenance being performed.