Routine maintenance, Notice – Autoquip SERIES 35 LOW PROFILE User Manual
Page 31

ROUTINE MAINTENANCE
NOTICE !
Use approved fluids only! Use of unauthorized fluids may
cause damage to seals and hosing.
DO NOT USE:
• Automatic Transmission Fluid (ATF)
• Hydraulic Jack Oil
• Hydraulic
Fluids
• Brake
Fluids
BLEEDING AIR FROM THE SYSTEM
1. Bleed any air which may have been entrapped in the hydraulic system by raising
the lift to approximately 50% of its full travel, then lower back down completely.
2. Hold the “DOWN” button for approximately 60 seconds.
3. Repeat this process five or six times.
4. Should the above steps not correct the problem, contact Autoquip to obtain
instruction for further action.
5. Clean up any spilled oil. Used oil should be discarded as it may contain flushed
contaminates from the line.
31