Troubleshooting analysis – Autoquip BASCULE BRIDGE - DOUBLE LEAF User Manual

Page 43

Advertising
background image

PROBLEM

POSSIBLE CAUSE AND SOLUTION

Bridge raises slowly.

• The structural members of the bridge may be

binding.

• The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

• The hydraulic line or hose may be leaking.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• Check the oil level in the reservoir.

• The motor voltage/wiring may be incorrect.

• The suction screen may be clogged. Remove and

clean the screen. Drain and replace the oil.

• The suction line may be leaking air due to a loose

fitting. Tighten as needed.

• The breather holes in the reservoir fill plug may be

clogged. Remove and clean.

• The power unit pump may be defective.

Bridge lowers slowly.

• The structural members of the bridge is binding.

• The tubing or hose is obstructed or broken. Where

pipe is used, check for obstruction in the line.

• The oil viscosity is not suited for the environmental

conditions. Refer to “Routine Maintenance” section
for oil recommendations.

• The return filter may be clogged due to dirt or

damage.

TROUBLESHOOTING ANALYSIS

43

Advertising