Danger, These cables are not jumper cables, This situation is extremely dangerous – Battery Tender Plus GEL 12V @ 1-25A (PN 021-0156) User Manual
Page 2: Like polarities must connect to be safe
DELTRAN BATTERY TENDER
®
PLUS
Installation & Mounting Instructions
________________________________________________________________________________________________________
Deltran Corporation, 801 International Speedway Blvd., DeLand, FL 32724 Page
2 of 2
Phone 386-736-7900 FAX 386-736-0379
www.batterytender.com
Battery
POS
LIKE POLARITIES MUST CONNECT TO BE SAFE.
Covered Socket
is Negative
A utomotive Sty le Blade Fuse
3.0 or 7.5 A mp
Covered Socket
is Pos itiv e
Expos ed Pin
is Pos itiv e
Quic k Dis connec t
s ame as used on
081-0069-6
Battery Tender Plus
Fus ed Ring Terminals w ith
Quic k Dis connec t
PN 081-0069-6
Ring Terminals : A pprox
5/16" Ins ide Diameter
9/16" Outside Diameter
Expos ed Pin
is Negative
NEG
CONNECTING OPPOSITE POLARITIES
CAUSES A DANGEROUS SHORT CIRCUIT.
NEVER
CONNECT
THESE
2 PLUGS!!!
NEG
POS
Battery
Cov ered Soc ket
is Pos itive
Ex posed Pin
is Negativ e
NEG
POS
Battery
Ex posed Pin
is Negativ e
Covered Soc ket
is Pos itiv e
The following picture shows a typical connection between the 12 Volt Battery Tender Plus (PN 021-0128),
the fused ring terminal cable assembly (PN 081-0069-6) and a 12 Volt lead-acid battery.
DANGER:
NEVER CONNECT THE QUICK DISCONNECT
PLUGS TOGETHER ON TWO (2) DC CABLE ASSEMBLY
ACCESSORIES THAT ARE BOTH CONNECTED TO BATTERIES.
THESE CABLES ARE NOT JUMPER CABLES!!
EVEN A RELATIVELY SMALL 18 TO 22 AMP HOUR MOTORCYCLE
BATTERY CAN GENERATE
SEVERAL HUNDRED, MAYBE EVEN
MORE THAN ONE THOUSAND AMPERES
WHEN THE TERMINALS
ARE SHORT CIRCUITED!
Insulation will melt, and virtually vaporize. Conductors will turn bright orange
and any combustible material that is nearby will very likely begin to burn.
THIS SITUATION IS EXTREMELY DANGEROUS.
!