Dc label backlight and circuit status system, Circuit breaker modules – Blue Sea Systems 1408 M-Series Dual Circuit Plus, Main + 3 Position CLB Vertical User Manual

Page 8

Advertising
background image

DC LABEL BACKLIGHT AND CIRCUIT STATUS SYSTEM

CIRCUIT BREAKER MODULES

The label backlighting and circuit status indicator is pre-wired for
12 Volts DC:
1. Connect +12 Volts to the +12V DC quick-connect terminal (piggy back lug
on panels with jumper wires) on the LED circuit board.
2. Connect the negative of the battery system to the NEG quick-connect
terminal (piggy back lug on panels with jumper wires) on the LED
circuit board.

To convert the label backlighting and circuit status indication to
24 Volts DC:
1. Replace the 12 Volt DC LED harness with a 12 to 24 Volt DC Conversion
Kit (PN 4113, not included with the panel).
Note: 360 panels with more than one module have backlight jumper
wires connecting modules. These jumper wires must be moved when
connecting to 24 Volts DC.
2. Move jumper wires from the +12V DC quick-connect terminal to the
+24V DC quick-connect terminal on the LED circuit board.
3. Connect +24 Volts to the +24V DC quick-connect terminal (piggy back lug
on panels with jumper wires) on the LED circuit board.
4. Connect the negative of the battery system to the NEG quick-connect
terminal (piggy back lug on panels with jumper wires) on the LED
circuit board.

6

For more information go to www.bluesea.com

+12V DC

+24V DC

NEG.

12V DC LED harness

12V DC quick connect terminal

12V DC LED circuit board

24V DC quick connect terminal

NEGATIVE quick connect terminal

Advertising
This manual is related to the following products: